Elevator cabin stress load cell:UC-AP-B
Description:
SUMMIT Elevator Cabin load cell sensors UC-AP-B are supplied with their own integral rubber mounting arrangement, specifically designed for installation below the elevator & lift car. They easily mount under the cab and are extremely accurate, The UC-AP series load cell sensor are designed for use with new passenger lift up to 3200kg load (4pcs)
Note: Under cab sensors UC-AP series are not recommended for lift modernization or retrofit.
- Anodised aluminium construction
- Up to 4x800kg: 3200kg load (4 sensors)
- High accuracy,USB interface or plug
- Individual sensor can be replaced
- Perfect for new installations
- Load cell for installation under elevator cabin.
- Mounted on a silent-block pad that avoids the transfer of vibrations .
- Connected to the unit control of the OMS-560 series and able to install a quantity of 4 cells in parallel, and max up to 8pcs load cell UC-AP/UC-AP-B/UC-AP-C
- Adjustable locking screw to adjust the unevenness of the bottom of the car during assembly
Model | UC-AP | UC-AP-B | UC-AP-C |
Rated Load | 800kg | 800kg | 800kg |
Rated Output | 2.0+-0.02%mv/v | 2.0+-0.02%mv/v | 2.0+-0.02%mv/v |
Total error | +/-0.5% F.S | +/-0.5% F.S | +/-0.5% F.S |
Repeatability | +/-0.5% F.S. | +/-0.5% F.S. | +/-0.5% F.S. |
Creep 30min | +/-0.05% F.S/30min | +/-0.05% F.S/30min | +/-0.05% F.S/30min |
Zero Balance | +/-1% F.S. | +/-1% F.S. | +/-1% F.S. |
T C SPAN | +/-0.02% F.S./10 degree Celsius | +/-0.02% F.S./10 degree Celsius | +/-0.02% F.S./10 degree Celsius |
Operation temperature range | -30 to 70 degree Celsius | -30 to 70 degree Celsius | -30 to 70 degree Celsius |
Input Resistance | 1030+/-10 ohm | 1030+/-10 ohm | 1030+/-10 ohm |
Output Resistance | 1000M+/-2 ohm | 1000M+/-2 ohm | 1000M+/-2 ohm |
Safe Overload | 150% F.S. | 150% F.S. | 150% F.S. |
Ultimate Overload | 200% F.S. | 200% F.S. | 200% F.S. |
Construction | Aerometal | Aerometal | Aerometal |
Protection Class | IP68 | IP68 | IP68 |
Insulation impedance | ≥5000Ω | ≥5000Ω | ≥5000Ω |
Cable length | 2.5m(black) | 2.5m(grey) | 5m(grey color) |
Connection type | USB interface | Terminal Plug | Terminal plug |
For traction elevator lifts, We SUMMIT provide a wide range of elevator load weighing device and it can suit different installation position requests, and usually there are 4 ways to mount it:
- Under elevator cabin (cab load cells)
- Clamped on the wire rope (wire rope load cells)
- Between the wire rope hitch plate such as RHP-E, RHP-F, RHP-G and so on. the customized load cells are available on requests(rope hitch compression load cells)
- Mounted on the elevator car frame to detect the beam deformation (tension link load cell, cross head load cell)


